Malta Data Center

NetShop ISP operates via two datacenters (NSMT01 , NSMT02) in Malta (ISO 27001 and PCI DSS certified) are housed within two state-of-the-art facilities with a total capacity of approximately 600 rack cabinets on a total of 1200m² usable floor space. The datacenters are situated in a light industrial area where there are no hazards or nearby possible business that might put the datacenter's operations and our customers in a risk. Our expansion in Malta is constant in order to serve our existing and future customers in the igaming and betting industry, as well as Banks and other institutions in the Forex and Financial industries.

The Data Centers are operating via two main Internet Service Providers, GO and Vodafone, which have submarine cables terminating in Sicily and passing via diverse routes. We have a redundant and fault tolerant network topology with links cross-connecting our sites and carriers. All carriers are present at both sites and the external links at one site can operate as a failover backup for the links at the other site.

Network Infrastructure

Our Malta Datacenters are operating via two main Internet Service Providers, GO and Vodafone, which have submarine cables terminating in Sicily and passing via diverse routes. We have a redundant and fault tolerant network topology with links cross-connecting our sites and carriers. All carriers are present at both sites and the external links at one site can operate as a failover backup for the links at the other site.

Security & Access Control

The datacenter has multiple CCTV installations covering the datacenter and all perimeters which are monitored 24x7 by the security staff. All CCTV recording tapes are securely kept in premises for 90 days. In addition to the presence of multiple man-traps, the datacenters are enhanced with door access systems to control movement and access throughout the facility.

Access is only permitted to pre-authorized visitors. All visitors are escorted by our staff which also follow a sign in/out procedure.

Our customer's space is protected by keypad/swipe systems and each individual rack is mechanically locked. Equipment and Rack cabinets can also be kept in a caged area upon customers' special request.

Cooling System

Our datacenters utilize a strong HVAC system which safeguards both a stable airflow and a temperature/humidity control.

Redundant A & B cooling systems and pipe work route to the rooftop condenser system and 2N+2 pump system to circulate chilled water to the data centre.

The data halls are designed and built with hot and cold aisle zones with the possibility of closed cold corridors. All major equipment have minimum 2N redundancies and all data halls' temperature is based on ASHRAE Class 1 specifications.